Description
Human LGMN ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing. Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed. Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and collect cells by centrifugation at 1000 × g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash the collected cells three times with ice-cold PBS and resuspend them in 150-200 μL of PBS per 1 × 10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500 × g for 10 minutes at 2-8°C, and collect the supernatant for analysis. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit utilizes a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a legumain (LGMN) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by HRP peroxidase and to yellow by acid. The intensity of the color is positively correlated with the amount of legumain (LGMN) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Legumain ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Asparagine endopeptidase (LGMN) is a proteolytic enzyme from the C13 peptidase family that utilizes the thiol group of cysteine residues as a nucleophile to hydrolyze peptide bonds (hence, it is also called a cysteine protease). It is also known as citvac, proteinase B, hemoglobinase, PRSC1 gene product, vicilin peptide hydrogenase, and legume endopeptidase. It is encoded by the LGMN gene (formerly symbolized as PRSC1). It hydrolyzes substrates C-terminal to asparagine residues. It can be detected in spleen, liver, brain, testicular tissue, and heart, and is primarily localized in lysosomes and endosomes. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.312-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Serum, plasma, tissue homogenates, cell lysates and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.8 ★★★★★
Based on 1390 reviews
Sort
Product Reviews
★★★★★ 5
Great scale that needs some improvements to be perfect
Color: White, Color: White
Very accurate scale, looks good in white, timer works nicely and I do like the concept of the ratio conversion. Shown in photos with 0 measurement drift over time, even without the silicone mat.
To make this the best scale in the price range, I would change:
- The auto timer function. Timing currently stops if you pick up the brew to swirl; you must completely restart the process if you do happen to pick it up. I would change that to only stop on user input (pressing a button).
- The ratio conversion. Why offer XX.0 precision if you can only change the ratio in whole amounts? I'd suggest offering 0.1 increments, selectable with +/- buttons instead of cycling through.
- The silicone mat is not well affixed and slides around. Kind of useless as-is and I just keep it off. I would wrap the whole thing around the measurement platform, similar to how the Greater Goods scale does it, to really keep it secure.
It's not perfect, but for the price, it's a 4.5/5 for me. Rounding up to 5 since a 4 is considered "bad" by today's online rating standards.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 22, 2025
★★★★★ 5
IMO, a filter coffee lovers best scale option on a budget. Solid grade A choice.
Color: Black
I have two other .1mg "coffee" or food scales that I used regular for pour overs. I saw this has 4x display on real time flow rate, g/mg weight, timer, and grounds to water ratio for a solid price and purchased this after reading some reviews. One of my scales has these features, but the workflow on this scale just clicked a ton better for me.
The beep isn't super loud annoying which is a major relief, as I just couldn't keep sound on on my other scale due to that trigger honestly. I tried brew mode immediately and will now only use that when making a pour over. Loved the beep alerting when I finally hit the proper ratio and I like it keeps my final info on screen after the brew for my study. I can actually practice my technique now and not have split attention as much.
This is still compact, but fits a larger carafe well whereas my other scale is a better fit for the espresso machine. The display is clear and buttons have a slight tactile sensation from the print, but are still the capacitive touch based style. I tested it with weights and it is my most accurate scale, it hit the .1g accurately every time or at worst would fluctuate back and forth quickly from the true value (more than enough for me to trust it). It updates and tares from power on fairly fast, it reacts fast enough to touch to not make me pause much.
My nitpicks are that the front clear matte plastic isn't quite uniform flat viewed at an off angle giving it a cheaper look, but that doesn't affect functionality at all and truth is, it really was very affordable for the feature set I feel.
The second nitpick was that the scale's mat does not grip well or fit securely over prompting it to move around easily. For this I had to modify using some rubberized grip tape on the surface of scale underneath the mat itself. Now it doesn't slide from vibration and if any pressure down it doesn't slip. I could have removed it totally, but it is attractive and useful once stabilized. With that modification done, I can fully recommend this scale for filter coffee lovers at any price. Great product, hopefully lasts me a long time.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 16, 2025
★★★★★ 5
Top of the line scale.
Color: Black
Fantastic scale. The best coffee scale I have ever owned and can be used for all kinds of kitchen items as well.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 5, 2026
★★★★★ 5
Product was as described and meet my need for a scale measuring 0.1 g
Color: Black
Product was as described. Works well. I use it for measuring the amount of coffee for my drip coffee maker. I have not done any testing with respect to actual accuracy so cannot comment. But it seems close to the other scale that I have that only measures to the nearest gram. Construction seems good. Nice looking unit.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 12, 2026
★★★★★ 4
Nice scale
Color: Black
Works as expected, nice size. Makes a big difference when adjusting espresso extraction. I haven't used the timer. One improvement for my use would be to move the power switch from the back to the front, on the side or on the control panel.
WAS THIS REVIEW HELPFUL?YesReportShare